LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
350W AC/DC
350 Watt
AC/DC high wattage powe r s upplie s with PFC
Notes
FEATURES
1
The unit must be powered up into the recommended minimum loads to
ensure the outputs come up.
2
3
Combined maximum output power for Aux. 1, 2 and 3 is 220W.
For models -9604 and -9692, on the aux 1 channel, output ripple and
noise is measured 6 inches down the output cables through a 1 foot long
twisted pair terminated with a parallel combination of a 10µF electrolytic
and a 0.1µF ceramic capacitors. For all other channels on all models,
ripple and noise is measured directly at the output terminals.
No shutdown or latch-up occurs; voltage is internally limited to specified
range.
Current share
(See Note 12)
Forced
Main output and
auxiliary 1 if 5V or 3.3V
Power OK
(See Note 13)
Asserted Low
0.4V
Main output >75%
4
Remote-sense
Main output and
auxiliary 1 if 5V or 3.3V
1
5
6
7
8
Aux. 2 tracks Aux. 3, Aux. 4 not adjustable.
Aux. 3 tracks Aux. 2.
Output is not adjustable.
System inhibit
Asserted high
Asserted low
Inhibits all outputs
CMP350-9604 rated operation:
Power fail detect
(See Note 13)
Indicates loss of AC
4ms warning
Graph 1
8A
15A
10A
5A
10A
Sum of 12V
Channel
Loads*
RATED
OPERATION
AC INPUT
OUTPUT
0A
5A
10A
15A
20A
PFD SIGNAL
3.3 V Channel Load
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
POWER GOOD SIGNAL
t1
t2
t1 Varies with line and load
t2 ≥ 4ms
t1
+ t2 ≥ 20ms
The auxiliary channels must share power as indicated by graph 1.
The maximum output power is 220W.
CMP350-9692 rated operation:
9
(14)
EXTERNAL OUTPUT TRIMMING
Main channel trim connections
12CH1
Graph 2
8A
15A
10A
5A
10A
Sum of 12V
Channel
Loads*
RATED
OPERATION
TRIM
UP/DOWN
TRIM
UP
TRIMAIN
GND1
0A
5A
10A
15A
TRIM
DOWN
5V Channel Load
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
Aux. 1 channel trim connections. (-9601, -9602, -9603, 9606)
Aux. 2 channel trim connections (-9604, -9692)
The auxiliary channels must share power as indicated by graph 2.
The maximum output power is 220W.
10 A minimum of 300LFM of forced air cooling is required for proper
operation of the CMP350.
12CH2
11 All outputs must be derated linearly from maximum specified loads during
operation above 50°C.
12 Current share is a single wire share circuit that allows the main output on
multiple CMP350 units to be operated in parallel. Auxiliary channels share
on -9604 and -9692 models by connecting the CSAUX channel.
13 The power fail detect and power OK signals are open-collector outputs
which will sink 40mA or less in the low state and should be pulled up to a
bias voltage with an appropriately sized resistor.
TRIM
UP/DOWN
TRIM
UP
TRIMAUX
GND2
TRIM
DOWN
Min.
0V
Max.
0.4V
-40mA
40V
VOL
IOL
0A
4V
VOH
Aux. 1 channel trim connections (-9604, -9692)
The system inhibit and output inhibit signals require a current source to be
asserted high.
AUX1SET
GND3
Min.
3.5V
0mA
Max.
15.0V
-10mA
VIH
IIH
TRIM
UP/DOWN
14 Connection from TRIMAUX2 to AUX1SET causes the output for Ch. aux. 1
on models -9604 and -9692 to regulate at its nominal factory set voltage.
15 3 orthogonal axes, random vibration, 10 minute test per axes.
16 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
TRIMAUX2
TRIMAUX2
TRIMAUX2 is connected to
AUX1SET by a factory fitted
jumper to ensure CH. 1
regulates at the nominal
set voltage
To trim CH1, remove the
jumper and connect a resistor
between GND3
and TRIMAUX2
http://www.artesyn.com