BXA10 Series  
S i n g l e a n d d u a l o u t p u t  
DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
INPUT  
OUTPUT  
VOLTAGE  
5.0V  
OUTPUT  
INPUT  
TYPICAL  
EFFICIENCY  
81%  
REGULATION (Typ.)  
MODEL  
OVP  
(1)  
(3)  
VOLTAGE  
9-18VDC  
9-18VDC  
9-18VDC  
18-75VDC  
18-75VDC  
18-75VDC  
18-75VDC  
CURRENT CURRENT  
LINE  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
LOAD  
±0.5%  
±0.5%  
±0.5%  
±0.5%  
±0.5%  
±0.5%  
0.5%  
NUMBER  
2.0A  
0.67A  
1.1A  
1.05A  
1.05A  
0.26A  
0.26A  
0.25A  
0.25A  
6.2VDC  
18VDC  
12VDC  
6.8VDC  
12VDC  
30VDC  
36VDC  
BXA10-12S05  
BXA10-12S15  
BXA10-12D05  
BXA10-48S05  
BXA10-48D05  
BXA10-48D12  
BXA10-48D15  
15.0V  
85%  
±5.0V  
±1.0A  
2.0A  
81%  
5.0V  
82%  
±5.0V  
±1.0A  
±0.416A  
±0.333A  
82%  
±12.0V  
±15.0V  
84%  
84%  
Notes  
PIN CONNECTIONS  
1
2
At nominal input and output voltage and maximum load.  
Output ripple can be reduced to <50mV with the addition of a 33µF, 25V,  
AVX-TPS (or equivalent) tantalum capacitor. Consult factory for further  
information.  
For units with optional remote ON/OFF, please add the suffix ‘-S’ to the  
model number: e.g. BXA10-48S05-S. Maximum open pin voltage 14VDC.  
Assumes balanced loads on dual output models.  
High impedance source/long input power cable may necessitate the  
introduction of an input filter.  
Typical 9-18VDC model start-up voltage is 9V. Maximum start-up voltage  
is 9.5V (>0°C) or 9.7V (<0°C).  
PIN NUMBER  
SINGLE OUTPUT  
+Vin  
DUAL OUTPUT  
+ Vin  
1
2
3
Vin  
Vin  
4
5
3
+ Vout  
+ Vout  
4
No Pin  
Common  
Vout  
6
7
8
5
Vout  
It is recommended that an IEC127, 250V, fast blow fuse is used rated at  
4A for nominal 12V models and 2A for 48V models.  
To achieve compliance to EN55022-A and FCC part 15 Class A, external  
capacitors of the following values are needed:  
6*  
Remote ON/OFF  
Remote ON/OFF  
* Optional remote ON/OFF pin. Add Suffix ‘-S’ to the model number, Note 3.  
Model  
C1*  
C2  
C3  
BXA10-12xxx  
BXA10-48xxx  
10µF film, 25V  
10µF film, 100V  
0.22µF film  
0.22µF film  
0.22µF film  
0.22µF film  
(C2, C3 voltage rating application dependent)  
* Siemens P.N. B32512-J1106-J or equivalent.  
www.a rte s yn.com  