AWT6331
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
Supply Voltage (VCC and VBATT
Mode Control Voltage (VMODE
Enable Voltage (VEN
RF Input Power (PIN) to PA
RF Input Power (PIN) to Switch
Storage Temperature (TSTG
MIN
MAX
+5
UNIT
V
)
0
0
)
+3.5
+3.5
+10
+20
+150
V
)
0
V
-
dBm
dBm
°C
-
)
-40
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure
to absolute ratings for extended periods of time may adversely affect
reliability.
Table 3: Operating Ranges
PARAMETER
MIN
824
+3.2
TYP
-
MAX
849
UNIT
MHz
V
COMMENTS
Operating Frequency (f)
Supply Voltage (VCC and VBATT
)
+3.4
+4.2
+2.2
0
+2.4
-
+3.1
+0.5
PA "on", Switch "on"
PA "shut down"
Enable Voltage (VEN
)
V
V
+2.2
0
+2.4
-
+3.1
+0.5
PA Mode
Switch Mode
Mode Control Voltage (VMODE
RF Output Power (POUT
Case Temperature (T
)
)
27.5(1)
28.0
-
dBm
°C
CDMA
C
)
-30
-
+85
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Notes:
(1) For operation at VCC = +3.2 V, POUT is derated by 0.5 dB.
Data Sheet - Rev 2.1
3
10/2008