4. DC and Switching Characteristics
AGX51004-2.0
Operating Conditions
Arria® GX devices are offered in both commercial and industrial grades. Both
commercial and industrial devices are offered in –6 speed grade only.
This chapter contains the following sections:
■
■
■
■
■
■
■
■
■
■
■
■
“Operating Conditions”
“Power Consumption” on page 4–25
“I/O Timing Model” on page 4–26
“Typical Design Performance” on page 4–32
“Block Performance” on page 4–84
“IOE Programmable Delay” on page 4–86
“Maximum Input and Output Clock Toggle Rate” on page 4–87
“Duty Cycle Distortion” on page 4–95
“High-Speed I/O Specifications” on page 4–100
“PLL Timing Specifications” on page 4–103
“External Memory Interface Specifications” on page 4–105
“JTAG Timing Specifications” on page 4–106
Table 4–1 through Table 4–42 on page 4–25 provide information on absolute
maximum ratings, recommended operating conditions, DC electrical characteristics,
and other specifications for Arria GX devices.
Absolute Maximum Ratings
Table 4–1 contains the absolute maximum ratings for the Arria GX device family.
Table 4–1. Arria GX Device Absolute Maximum Ratings
Symbol Parameter
Supply voltage
(Note 1), (2), (3) (Part 1 of 2)
Conditions
Minimum
–0.5
Maximum
1.8
Units
V
VCCINT
VCCIO
VCCPD
VI
With respect to ground
Supply voltage
With respect to ground
–0.5
4.6
V
Supply voltage
With respect to ground
–0.5
4.6
V
DC input voltage (4)
DC output current, per pin
Storage temperature
—
—
–0.5
4.6
V
IOUT
–25
40
mA
C
TSTG
No bias
–65
150
© December 2009 Altera Corporation