内容描述: 这chapterdescribes的电气特性,开关特性,以及Cyclone III器件的I / O时序。词库也包含供您参考 [This chapterdescribes the electric characteristics, switching characteristics,and I/O timing for Cyclone III devices. A glossary is also included for your reference]
分类和应用: 开关
文件页数/大小: 34 页 / 836 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号3.0-VLVTTL的Datasheet PDF文件第1页浏览型号3.0-VLVTTL的Datasheet PDF文件第2页浏览型号3.0-VLVTTL的Datasheet PDF文件第3页浏览型号3.0-VLVTTL的Datasheet PDF文件第5页浏览型号3.0-VLVTTL的Datasheet PDF文件第6页浏览型号3.0-VLVTTL的Datasheet PDF文件第7页浏览型号3.0-VLVTTL的Datasheet PDF文件第8页浏览型号3.0-VLVTTL的Datasheet PDF文件第9页  
1–4  
Chapter 1: Cyclone III Device Datasheet  
Electrical Characteristics  
Recommended Operating Conditions  
This section lists the functional operation limits for AC and DC parameters for  
Cyclone III devices. The steady-state voltage and current values expected from  
Cyclone III devices are provided in Table 1–3. All supplies must be strictly monotonic  
without plateaus.  
(1), (2)  
Table 1–3. Cyclone III Devices Recommended Operating Conditions  
Symbol  
Parameter  
Conditions  
Min  
Typ  
Max  
Unit  
(3)  
VCCINT  
Supply voltage for internal logic  
1.15  
1.2  
1.25  
V
Supply voltage for output buffers, 3.3-V  
operation  
3.135  
2.85  
3.3  
3
3.465  
3.15  
V
V
V
V
V
V
V
Supply voltage for output buffers, 3.0-V  
operation  
Supply voltage for output buffers, 2.5-V  
operation  
2.375  
1.71  
2.5  
1.8  
1.5  
1.2  
2.5  
2.625  
1.89  
(3), (4)  
VCCIO  
Supply voltage for output buffers, 1.8-V  
operation  
Supply voltage for output buffers, 1.5-V  
operation  
1.425  
1.14  
1.575  
1.26  
Supply voltage for output buffers, 1.2-V  
operation  
Supply (analog) voltage for PLL  
regulator  
(3)  
VCCA  
2.375  
2.625  
(3)  
VCCD_PLL  
Supply (digital) voltage for PLL  
Input voltage  
1.15  
–0.5  
0
1.2  
1.25  
3.6  
V
V
VI  
VO  
Output voltage  
VCCIO  
85  
V
For commercial use  
For industrial use  
For extended temperature  
For automotive use  
Standard power-on reset  
0
°C  
°C  
°C  
°C  
–40  
–40  
–40  
100  
125  
125  
TJ  
Operating junction temperature  
50 µs  
50 µs  
50 ms  
3 ms  
10  
(5)  
(POR)  
tRAMP  
Power supply ramp time  
(6)  
Fast POR  
Magnitude of DC current across  
PCI-clamp diode when enabled  
IDiode  
mA  
Notes to Table 1–3:  
(1) VCCIO for all I/O banks must be powered up during device operation. All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and  
must be powered up and powered down at the same time.  
(2) VCCD_PLL must always be connected to VCCINT through a decoupling capacitor and ferrite bead.  
(3) The VCC must rise monotonically.  
(4) All input buffers are powered by the VCCIO supply.  
(5) POR time for Standard POR ranges between 50–200 ms. Each individual power supply should reach the recommended operating range within  
50 ms.  
(6) POR time for Fast POR ranges between 3–9 ms. Each individual power supply should reach the recommended operating range within 3 ms.  
Cyclone III Device Handbook  
Volume 2  
July 2012 Altera Corporation