Wire > Hook-Up Wire > 600 V
Hook-Up Wire
600 V, PVC
• -20°C to +75°C (THW)
• -20°C to +60°C (TW)
UL AWM 1015, 1028, 1230,
1231, 1232, 1283, 1284 VW-1
UL MTW (22 to 4/0 AWG)
UL THW (6 to 1/0 AWG)
CSA AWM I A/B FT1 and
TEW 105
Materials
• Stranded or solid tinned
copper conductor
• PVC insulation
Operating Temperature
Availability
• -20°C to +105°C (AWM, TEW)
• -20°C to +90°C (MTW)
100 ft (30.5 m)
1000 ft (305 m)
Insulation
Nominal
Wire Size
Part No.
Stranding
Thickness
Diameter
UL Style
Colors
AWG
26
24
24
22
22
22
20
20
20
18
mm2
0.14
AWG
7/34
Solid
7/32
Solid
mm
7 x 0.16
1 x 0.51
7 x 0.20
1 x 0.64
Inch
mm
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
1.19
Inch
mm
2.11
2.13
782607*
782401*
3070*
782201
782207T
3071
782010T
3073
782001
781816T
3075
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.047
0.063
0.063
0.063
0.063
0.082
0.082
0.082
0.082
0.082
0.082
0.083
0.084
0.088
0.089
0.094
0.094
0.101
0.101
0.096
0.111
1015, 1230
1015, 1230
1015
1015, 1230
1015, 1230
1015
1015, 1230
1015
1015, 1230
1015, 1230
1015
1015, 1230
1015, 1230
1015
1015, 1230
1015
Z2, 0 - 9
Z2, 0 - 9
Z1, 1 - 10, 28
Z2, 0 - 9
Z2, 0 - 9
Z1, 1 - 10, 28, 29
Z2, 0 - 9
Z1, 1 - 10, 28
Z2, 0 - 9
Z2, 0 - 9
Z1, 1 - 10, 28, 29
Z2, 0 - 9
Z2, 0 - 9
Z1, 1 - 10, 28, 29
Z2, 0 - 9
Z1, 1 - 10, 28, 29
Z1, 1 - 4
0.20
0.23
0.32
0.35
0.35
0.51
0.51
0.52
0.81
2.24
2.26
2.39
2.39
2.57
2.57
2.44
2.82
2.82
2.64
2.92
3.15
7/30
7/30
7 x 0.25
7 x 0.25
10/30
10/30
Solid
16/30
16/30
Solid
Solid
26/30
Solid
10 x 0.25
10 x 0.25
1 x 0.81
16 x 0.25
16 x 0.25
1 x 1.02
1 x 1.29
26 x 0.25
1 x 1.63
18
0.81
0.111
0.104
0.115
781801
781601
3077
18
16
16
0.82
1.31
1.32
0.124
0.128
0.138
0.157
0.145
0.166
0.184
0.263
0.336
0.395
0.461
0.465
0.540
0.547
0.592
0.647
0.768
0.754
781401
3079
3080
781201
781001
3081
788133
786133
784133
782665
782133
781259
781836
780001
780002
780003
780004
14
14
12
2.08
2.08
3.29
3.31
5.26
5.32
8.61
13.57
21.55
33.72
34.45
41.96
42.39
52.98
67.43
84.47
106.93
3.25
3.51
41/30
65/30
Solid
41 x 0.25
65 x 0.25
1 x 2.06
3.99
3.68
4.22
4.67
6.68
8.53
10.03
11.71
11.81
13.72
13.89
15.04
16.43
19.51
19.15
1015
12
1015, 1230
1015, 1230
1015
Z2, 0 - 9
Z2, 0 - 9
Z1, 1 - 4
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
Z2, 0 - 9
10
10
8
6
4
2
2
1
1
1/0
2/0
3/0
4/0
Solid
1 x 2.59
105/30
133/29
133/27
133/25
665/30
133/23
259/25
836/30
1045/30
1330/30
1666/30
2109/30
105 x 0.25
133 x 0.29
133 x 0.36
133 x 0.45
665 x 0.25
133 x 0.57
259 x 0.45
836 x 0.25
1045 x 0.25
1330 x 0.25
1666 x 0.25
2109 x 0.25
1028, 1231
1283, 1232
1283, 1232
1283, 1232
1283, 1232
1284, 1232
1284, 1232
1284, 1232
1284, 1232
1284, 1232
1284, 1232
1.60
1.60
1.60
1.60
2.08
2.08
2.08
2.08
2.08
2.08
T indicates top coat conductors.
*Not MTW
Insulation Colors Z1
Insulation Colors Z2
1 White
2 Black
3 Red
5 Yellow
6 Blue
7 Brown
9 Slate
10 Violet
28 Green/Yellow
29 Yellow/Green
0 Black
1 Brown
2 Red
4 Yellow
5 Green
6 Blue
8 Slate
9 White
4 Green
8 Orange
3 Orange
7 Violet
These wires also available in 500 ft (152 m) put-ups.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.