 浏览型号2032-C0630HX-30B的Datasheet PDF文件第1页浏览型号2032-C0630HX-30B的Datasheet PDF文件第2页浏览型号2032-C0630HX-30B的Datasheet PDF文件第3页浏览型号2032-C0630HX-30B的Datasheet PDF文件第5页浏览型号2032-C0630HX-30B的Datasheet PDF文件第6页浏览型号2032-C0630HX-30B的Datasheet PDF文件第7页浏览型号2032-C0630HX-30B的Datasheet PDF文件第8页浏览型号2032-C0630HX-30B的Datasheet PDF文件第9页  
Safety Isolation System  
ElectroGuard  
Combination Systems with Fusible Disconnect Switch  
Product Selection for Outside North America (see page 12-19 for Ordering Instructions)  
3-Phase Max. kW Rating  
(50Hz)  
Catalogue Num ber ➊  
IP 54 Motor Control  
Am pere  
Rating  
Fuse Clip  
Rating/  
Centre Type  
Enclosure (with  
bussing)  
(AC-3) 230V 400V 500V 600V Typ e ➊  
IP 30 Enclosure  
IP 54 Enclosure  
IP 65 Enclosure  
2032*-C0630W -30D  
2032*-C0630W -31B  
2032*-C0630W -31D  
2032*-C0860W -31B  
2032*-C0630P -30D 2032*-C0630H -30D  
2032*-C0630P -31B 2032*-C0630H -31B  
2032*-C0630P -31D 2032*-C0630H -31D  
2032*-C0860P -31B 2032*-C0860H -31B  
2032-!0630H 30D  
2032-!0630H -31B  
2032-!0630H -31D  
2032-!0860H -31B  
630A DIN  
630  
200  
355  
450  
500 800A BS 88  
1600A DIN  
800A BS 88  
1250A  
600  
860  
250  
391  
500  
710  
560  
2032*-C0860P -32B 2032*-C0860H -32B  
2032*-C0860P -31D 2032*-C0860H -31D  
2032*-C1200P -32B 2032*-C1200H -32B  
2032-!0860H -32B  
2032-!0860H -31D  
2032-!1200H -32B  
2032-!1200H -31D  
2032*-C0860W -32B  
2032*-C0860W -31D  
2032*-C1200W -32B  
2032*-C1200W -31D  
BS 88  
1600A DIN  
1250A  
BS 88  
1200  
888 1043  
1600A DIN 2032*-C1200P -31D 2032*-C1200H -31D  
To order the Tim e Delay feature, add the following Cat. String to the end of the Catalogue Num ber shown in the table:  
Factory set 30 second time delay feature:  
-1TD  
Example: Catalogue Number 2032-C0180P -29B becomes Catalogue Number 2032-C0180P -29B-1TD to include the time delay feature.  
* Input Power Feed Catalogue Num ber Code  
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.  
Example: Catalogue Number 2032*-C0630P -31B becomes Catalogue Number 2032T-C0630P -31B for a “Top Feed” input power requirement.  
Input Power Feed  
Catalogue Num ber Code  
Top Feed  
T
B
Bottom Feed  
! Bussing Designation  
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.  
Example: Catalogue Number 2032-!0085H -27D becomes Catalogue Number 2032-E0085H -27D for “600A Line Side Incoming Bus and Outgoing Power  
Cables” bussing designation.  
Ty p e o f B u s s i n g ➊  
Catalogue Num ber Code  
600A Line Side Incoming Bus and Outgoing Power Cables  
1200A Line Side Incoming Bus and Outgoing Power Cables  
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus  
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus  
E
D
H
R
Input Line Voltage Code  
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.  
Example: Catalogue Number 2032-C0085W -26B becomes Catalogue Number 2032-C0085WN-26B for a 380V 50Hz Input Line Voltage application.  
Input Line Voltage  
220V 50Hz  
A
380-400V 50Hz 400-415V 50Hz 440V 50Hz  
500V 50Hz  
M
550V 50Hz  
C
Voltage Code for Catalogue Number  
N
G
B
Product Selection: Remote Lockout Station ➊  
Catalogue Num ber  
IP 54 Enclosure  
2030-RLSHG  
“System Isolated” Light Colour  
Green  
IP 30 Enclosure  
2030-RLSPG  
IP 65 Enclosure  
2030-RLSW G  
Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.  
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator  
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.  
Consult your local Rockwell Automation sales office for other time settings.  
Bus Type: Copper with tin plating. Consult factory for other types of bussing.  
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).  
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).  
12-9