Series AM15E-IZ
15 Watt | DC-DC Converter
Models
Dual output (continued)
Input
Output
Voltage
(V)
Output Current
max (A)
Ripple & Noise
typ
Isolation
(VDC)
Efficiency
(%)
Model
Voltage
(V)
AM15E-2405DH30IZ
AM15E-2412DH30IZ
AM15E-2415DH30IZ
AM15E-4805DH30IZ
AM15E-4812DH30IZ
AM15E-4815DH30IZ
18-36
18-36
18-36
36-75
36-75
36-75
±5
±12
±15
±5
±12
±15
±1.5
±0.62
±0.5
±1.5
±0.62
±0.5
50mVp-p
120mVp-p
150mVp-p
50mVp-p
120mVp-p
150mVp-p
3000
3000
3000
3000
3000
3000
80
82
84
76
83
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
9-18
18-36
37-75
Maximum
Units
12
24
48
VDC
Voltage range
Filter
π (Pi) Network
3.5 to 12VDC or open circuit
On
Off
12 Vin
24 Vin
48 Vin
Remote On/Off Control
0 to 1.2VDC or short circuit between pin 2 and 4; typical idle current 3mA
25
50
100
2
Absolute Maximum Rating
VDC
Permissible absolute maximum duration
Recommended Input Fuse (slow blow)
h
12 Vin
24 Vin
48 Vin
4A/250V
2A/250V
1A/250V
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
1500 & 3000
Maximum
Maximum
Units
VDC
MOhm
pF
3 sec
> 1000
1000
Capacitance
Output Specifications
Parameters
Conditions
Typical
Units
Voltage accuracy
±2
%
Short Circuit protection
Short Circuit restart
Continuous
Auto recovery
Over voltage protection
Over load protection
Zener diode clamp protection
Over 110% full load with auto-recovery
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Transient response recovery time
HL-LL
HL-LL
25-100%
25-100%
±0.5
±0.5
±0.5
±2
±0.05
300
%
%
%
%
%/oC
uS
25% load step
change
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only