欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM15CW-2412DZ 参数 Datasheet PDF下载

AM15CW-2412DZ图片预览
型号: AM15CW-2412DZ
PDF下载: 下载PDF文件 查看货源
内容描述: 15Watt | DC- DC转换器 [15Watt | DC-DC Converter]
分类和应用: 转换器
文件页数/大小: 4 页 / 287 K
品牌: AIMTEC [ AIMTEC ]
 浏览型号AM15CW-2412DZ的Datasheet PDF文件第1页浏览型号AM15CW-2412DZ的Datasheet PDF文件第3页浏览型号AM15CW-2412DZ的Datasheet PDF文件第4页  
Series AM15CW-Z  
15Watt | DC-DC Converter  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Case to Input  
Case to Output  
Resistance  
Capacitance  
Conditions  
3 sec  
Typical  
1600  
1600  
1600  
>1000  
Maximum  
Units  
VDC  
VDC  
VDC  
MOhm  
pF  
3 sec  
3 sec  
1200  
Output Specifications  
Parameters  
Conditions  
Typical  
Maximum  
Units  
Voltage accuracy  
±1  
%
25% load on one output - 100% load  
on second load  
Cross Regulation (Dual Output Models)  
±5  
%
Over voltage protection  
Over current protection  
Short Circuit protection  
Short circuit restart  
Line voltage regulation  
Load voltage regulation (Single)  
Load voltage regulation (Dual)  
Temperature coefficient  
Ripple & Noise  
Zener Diode Clamp  
Full Load  
120  
%
%
170  
Continuous  
Auto-Recovery  
±0.2  
HL-LL  
0% to 100% load  
0% to 100% balanced load  
%
%
%
±0.5  
±1  
±0.02  
100  
%/oC  
mV p-p  
%
20MHz Bandwidth  
Trim - Single output models only  
Voltage adjustment range  
10  
General Specifications  
Parameters  
Switching frequency  
Operating temperature  
Storage temperature  
Maximum case temperature  
Derating  
Conditions  
100% load  
With derating above +55°C  
Typical  
375  
Maximum  
Units  
KHz  
oC  
-40 to +85  
-40 to +125  
oC  
100  
95  
oC  
2.6  
%/ oC  
Cooling  
Humidity  
Case material  
Weight  
Free air convection  
% RH  
g
Nickel-coated copper  
18  
Dimensions (L x W x H)  
MTBF  
Maximum soldering temperature  
Transient recovery time  
Transient recovery deviation  
1.00 x 1.00 x 0.40 inches  
> 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)  
1.5mm from case for 10 sec 260  
25.40 x 25.40 x 10.16 mm  
oC  
µS  
%
Load step change 75% to 50% to 25%  
Load step change 75% to 50% to 25%  
250  
±3  
Safety Specifications  
Parameters  
Agency Approvals  
CE  
Standards  
EN 55022 Class A  
EN 61000-4-2 Perf. Criteria A  
EN 61000-4-3 Perf. Criteria A  
EN 61000-4-4 Perf. Criteria A (external 220uF/100V cap required)  
EN 61000-4-5 Perf. Criteria A (external 220uF/100V cap required)  
EN 61000-4-6 Perf. Criteria A  
EN 61000-4-8 Perf. Criteria A  
NOTE: also designed to meet IEC/EN 60950-1  
www.aimtec.com  
F 051e R11  
Tel: +1 514 620 2722  
2 of 4  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only