Series AM15C-Z
15Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Nominal
Typical
Maximum
Units
No load current
15
mA
12 Vin ON/OFF
24 Vin ON/OFF
48 Vin ON/OFF
8.5 /7
17/15
34/35
20
Under voltage lockout
VDC
Input reflected ripple current
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Case to Input
Case to Output
Resistance
Capacitance
Conditions
Typical
Maximum
Units
VDC
VDC
VDC
MOhm
pF
3 sec
3 sec
3 sec
1600
1600
1600
>1000
1200
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±1
%
25% load on one output - 100% load
on second load
Cross Regulation (Dual Output Models)
±5
%
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Zener Diode Clamp
Full Load
120
170
Continuous
Auto-Recovery
±0.2
%
%
HL-LL
0% to 100% load
0% to 100% balanced load
%
%
%
±0.5
±1
±0.02
100
%/oC
mV p-p
%
20MHz Bandwidth
Trim - Single output models only
Voltage adjustment range
±10
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Conditions
100% load
With derating above +65°C
Typical
375
Maximum
Units
KHz
oC
-40 to +85
-40 to +125
oC
105
95
oC
2.6
%/ oC
Cooling
Humidity
Case material
Weight
Free air convection
% RH
g
Nickel-coated copper
18
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
1.00 x 1.00 x 0.40 inches
> 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec 260
Load step change 75% to 50% to 25%
25.40 x 25.40 x 10.16 mm
oC
µS
%
250
±3
Transient recovery deviation
Load step change 75% to 50% to 25%
www.aimtec.com
F 051e R11
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)