Series AM15CW-FZ
15Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
Maximum
Units
%
±1
Over voltage protection
Over load protection
Zener Diode Clamp
% of Full Load at Nominal Input
120
110
%
%
Short Circuit protection
Short circuit restart
Continuous
Auto-Recovery
Line voltage regulation
Load voltage regulation (Single)
HL-LL
25% to 100% load
balanced load
±1.0
±1.0
±0.5
±5.0
±0.02
80
10
560
±5
±6
%
%
Load voltage regulation (Dual)
%
Unbalanced 25% to 100%
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Transient recovery time
%/oC
mV p-p
%
20MHz Bandwidth
Trim - Single output models only
Load step change 50%
di/dt = 0.8A/µsec
µS
Transient recovery deviation
%of Vo
3.3V models
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Potting Material
Weight
Conditions
100% load
With derating above +63°C
Typical
330
Maximum
Units
KHz
oC
-40 to +85
-55 to +125
oC
105
95
oC
Free air convection
% RH
g
Nickel-coated copper
Silicon Rubber (UL94V-0)
19.2
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
1.00 x 1.00 x 0.40 inches
> 1,580,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec 260
25.40 x 25.40 x 10.20 mm
oC
Pin Out Specifications
Single
+ V input
- V input
Dual
+ V input
- V input
Pin
1
2
3
4
5
On/Off Control
+ V output
Trim
On/Off Control
+ V output
Common
6
- V output
- V output
www.aimtec.com
F 051e R11
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only