Series AM15CW-NZ
15 Watt | DC-DC Converter
Output Specifications(Continued)
Parameters
Conditions
5% to 100% load
100% load
Typical
±0.5
Maximum
Units
%
Load voltage regulation
Temperature coefficient
±1
±0.03
100
0.5
±7
±5
%/oC
mV p-p
ms
Ripple & Noise
Transient recovery time
20MHz Bandwidth, 5-100% load
25% load step change
50
0.3
±3
±3
3.3/5V output
Others
Transient recovery deviation
25% load step change
%
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
3.3/5V output
300
270
100% load
KHz
Others
3.3/5V output
Others
-40 to +95
-40 to +105
See derating
curve
Operating temperature
oC
oC
Storage temperature
Cooling
-55 to +125
Free air convection
Humidity
95
% RH
Case material
Aluminum Alloy
Pin mountable
15
35
55
20
40
60
With optional -ST mounting plate:
With optional -STD mounting plate:
With optional -K Pin mountable
With optional -ST-K mounting plate:
With optional -STD-K mounting plate:
Pin mountable
Weight
g
1 x 1 x 0.46 inches
25.40 x 25.40 x 11.70 mm
With optional -ST mounting plate:
With optional -STD mounting plate:
With optional -K Pin mountable
With optional -ST-K mounting plate:
With optional -STD-K mounting plate:
2.99 x 1.24 x 0.84 inches 76.00 x 31.50 x 21.20 mm
2.99 x 1.24 x 1.02 inches 76.00 x 31.50 x 25.80 mm
Dimensions (L x W x H)
1 x 1 x 0.64 inches
25.40 x 25.40 x 16.20 mm
2.99 x 1.24 x 0.99 inches 76.00 x 31.50 x 25.20 mm
2.99 x 1.24 x 1.17 inches 76.00 x 31.50 x 29.80 mm
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
MTBF
Maximum soldering temperature
1.5mm from case for 10 sec
300
oC
Safety Specifications
Parameters
Designed to meet EN62368
CISPR32 / EN 55032, Class A, Class B with the recommended EMC circuit
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
IEC 61000-4-2, Contact ±6KV, Air ±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
Standards
Electrical Fast Transient / Burst Immunity IEC 61000-4-4, ±2KV with the recommended EMC circuit, Criteria A
Surge Immunity
RF, Conducted Disturbance Immunity
IEC 61000-4-5, L-L ±2KV with the recommended EMC circuit, Criteria B
IEC 61000-4-6, 3 Vrms, Criteria A
www.aimtec.com
F 051e R1
Tel: +1 514 620 2722
2 of 8
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only