Series AM15C-NZ
15 Watt | DC-DC Converter
5V output models
Trim down %
1
4.95
2
4.9
3
4.85
4
4.8
5
4.75
6
4.7
7
4.65
8
4.6
9
4.55
2.598
9
10
4.5
Vout (VDC)
Rt down (KΩ)
Trim up %
89.996
1
47.446
2
29.793
3
20.131
4
14.036
5
9.840
6
6.775
7
4.439
8
1.111
10
Vout (VDC)
Rt up (KΩ)
5.05
5.1
5.15
5.2
5.25
5.3
5.35
5.4
5.45
6.861
5.5
238.676
81.473
46.044
30.398
21.581
15.923
11.985
9.085
5.101
12V output models
Trim down %
1
11.88
493.692
1
2
11.76
299.052
2
3
11.64
210.127
3
4
11.52
159.185
4
5
11.4
6
11.28
103.042
6
7
11.16
85.932
7
8
11.04
72.764
8
9
10.92
62.316
9
10
10.8
Vout (VDC)
Rt down (KΩ)
Trim up %
126.173
5
53.823
10
Vout (VDC)
Rt up (KΩ)
12.12
704.035
12.24
156.520
12.36
81.479
12.48
51.675
12.6
12.72
25.695
12.84
18.874
12.96
13.917
13.08
10.152
13.2
35.677
7.195
15V output models
Trim down %
1
14.85
632.483
1
2
14.7
3
14.55
286.114
3
4
14.4
5
14.25
177.137
5
6
14.1
7
13.95
123.787
7
8
13.8
9
13.65
92.132
9
10
13.5
Vout (VDC)
Rt down (KΩ)
Trim up %
398.237
2
220.359
4
146.560
6
106.169
8
80.687
10
Vout (VDC)
15.15
15.3
15.45
94.242
15.6
15.75
40.616
15.9
16.05
21.791
16.2
16.35
12.190
16.5
Rt up (KΩ)
1457.699
190.174
58.954
29.381
16.321
8.961
24V output models
Trim down %
1
2
23.52
789.923
2
3
23.28
563.667
3
4
23.04
433.904
4
5
22.8
6
22.56
290.763
6
7
22.32
247.115
7
8
22.08
213.514
8
9
21.84
186.847
9
10
21.6
Vout (VDC)
23.76
Rt down (KΩ)
Trim up %
1284.000
1
349.754
5
165.170
10
Vout (VDC)
Rt up (KΩ)
24.24
814.689
24.48
177.714
24.72
92.138
24.96
58.264
25.2
25.44
28.788
25.68
21.057
25.92
15.440
26.16
11.176
26.4
40.107
7.827
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R1
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only