Series AM150QB-NZ
150 Watt | DC-DC Converter
AM150QB-4812SH22-NZ
Trim down %
1
2
3
4
5
11.4
6
7
11.16
88.332
7
12.84
21.274
8
11.04
75.164
8
12.96
16.317
9
10.92
64.716
9
13.08
12.552
10
10.8
56.223
10
13.2
9.595
Vout (VDC)
Rt down (KΩ)
Trim up %
11.88
11.76
11.64
11.52
11.28
496.092 301.452 212.527 161.585 128.573 105.442
1
2
3
12.36
83.879
4
12.48
54.075
5
12.6
38.077
6
12.72
28.095
Vout (VDC)
Rt up (KΩ)
12.12
706.435 158.920
12.24
AM150QB-4815SH22-NZ
Trim down %
1
2
14.7
3
4
14.4
5
6
14.1
7
8
13.8
9
13.65
98.623
9
16.35
11.507
10
13.5
86.082
10
16.5
8.808
Vout (VDC)
Rt down (KΩ)
Trim up %
14.85
14.55
14.25
13.95
965.116 508.787 339.586 251.370 197.224 160.605 134.188 114.231
1
2
15.3
3
15.45
67.878
4
15.6
46.190
5
15.75
33.499
6
15.9
25.168
7
16.05
19.279
8
16.2
14.896
Vout (VDC)
Rt up (KΩ)
15.15
269.667 113.379
AM150QB-4824SH22-NZ
Trim down %
1
2
3
4
5
6
7
8
9
10
Vout (VDC)
Rt down (KΩ)
Trim up %
Vout (VDC)
Rt up (KΩ)
23.76
23.52
23.28
23.04
22.8
22.56
22.32
22.08
21.84
21.6
1289.000 794.923 568.667 438.904 354.754 295.763 252.115 218.514 191.847 170.170
1
2
3
24.72
97.138
4
24.96
63.264
5
25.2
45.107
6
25.44
33.788
7
25.68
26.057
8
25.92
20.440
9
26.16
16.176
10
26.4
12.827
24.24
819.689 182.714
24.48
AM150QB-4848SH22-NZ
Trim down %
1
2
3
4
5
6
7
8
9
10
Vout (VDC)
47.52
47.04
46.56
46.08
45.6
45.12
44.64
44.16
43.68
43.2
Rt down (KΩ) 4953.999 2443.889 1606.786 1188.160 936.961 769.484 649.854 560.128 490.339 434.508
Trim up %
Vout (VDC)
Rt up (KΩ)
1
2
3
4
5
50.4
6
7
8
9
10
52.8
48.48
48.96
49.44
49.92
50.88
51.36
51.84
52.32
261.328 123.114 77.065 54.045 40.234 31.027 24.451 19.519 15.684 12.615
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R1
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only