Series AM12T-Z
12 Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Peak Input Voltage time
Input reflected ripple current
Quiescent Current
Nominal
Typical
Maximum
1000
Units
ms
mA p-p
mA
20
15
ON – High (3.0 ... 12Vdc) or open circuit;
On/Off Control
OFF – Low (0 ... 1.2Vdc) or Short circuit pin1 and pin 2/3
OFF idle current: 5.0 mA typ
Isolation Specifications
Parameters
Tested I/O voltage
Tested Case/Input and Output
Resistance
Conditions
Typical
Rated
1600
Units
3 sec
VDC
VDC
MOhm
pF
1600
>1000
1200
Capacitance
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
±1.2
Maximum
Units
%
Voltage balance
Dual output
HL-LL
0% Load to Full Load
0% Load to Full Load
±5
±0.5
±0.5
%
%
%
%
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
±1.0
Zener diode clamp
150
Continuous
Auto recovery
85
Full Load
%
Ripple & Noise
m Vp-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Derating
Cooling
Humidity
Case material
Potting material
Weight
Conditions
100% load
Full Load with Derating above 60ºC
Typical
330
Maximum
Units
KHz
oC
-40 to +85
-40 to +125
oC
100
95
oC
±0.02
2.5 % per 1ºC
Free air convection
%/oC
Above 60ºC
% RH
g
Nickel-coated Copper
UL94V-0 rated
18.0
Dimensions (L x W x H)
MTBF
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Agency Approval
CE
IEC 60950-1:2005 (2nd Edition); EN 60950-1: 2006
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
Standards
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only