Series AM10T-IZ
10 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1500
Units
VDC
MOhm
pF
60 sec
> 1000
470
Capacitance
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
Maximum
Units
%
±2
Short Circuit protection
Short Circuit restart
Continuous
Auto recovery
>110%
Over voltage protection
Over load protection
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Zener diode clamp
Auto recovery
HL-LL
0 – 100% full load
0 – 100% full load
VDC
Over 110% full load
±0.5
±0.5
±2
%
%
%
±0.05
%/oC
3.3 & 5V models
12 & 15V models
80 mV p-p
1% Vout p-p
Ripple & Noise
mV
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Case Temperature
Cooling
Conditions
100% load
Typical
300
Maximum
Units
KHz
oC
Derating above +50 oC
-40 to +75
-55 to +115
oC
+95
95
oC
Free air convection
Humidity
%
Case material
Nickel coated cooper
Weight
Dimensions (L x W x H)
MTBF
18
1.25 x 0.80 x 0.40 inches
g
Tolerance ±0.02 inch, ±0.5mm
31.80 x 20.30 x 10.20 mm
> 700 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Standards
Agency approvals
UL (pending)
EN 55022, class A
EN 55024
Safety
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)