Series AM10T-NZ
10 Watt | DC-DC Converter
Input Specifications(Continued)
Parameters
Nominal
Typical
Maximum
Units
On
3.5-12VDC or leave open
Off
Input Current when
Off
0-1.2VDC or connect to GND, idle current 6-10mA
Remote On/Off Control
10
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1500
Units
VDC
MOhm
pF
60 sec
> 1000
2000
Capacitance
Output Specifications
Parameters
Conditions
Positive Output
Negative Output
Typical
±0.5
Maximum
Units
%
Voltage accuracy
±1
Short Circuit protection
Short Circuit restart
Over voltage protection
Line voltage regulation
LL-HL
Continuous
Auto recovery
>110%
±0.2
±0.5
±0.5
±5
Zener diode clamp
Positive Output
Negative Output
5% – 100% full load
0% – 5% load
VDC
%
%
%
Load voltage regulation
Temperature coefficient
Transient recovery time
Transient recovery deviation
Full load
±0.03
0.3
%/oC
mS
%
25% load step change,
25% load step change
20Mhz bandwidth, 5%-
100% load
0.5
±5
±3
Ripple & Noise
40
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Cooling
Conditions
100% load
Derating above +71 oC
Typical
350
Maximum
Units
KHz
oC
-40 to +85
-55 to +125
oC
Free air convection
Humidity
Case material
Weight
95
%
g
Aluminum Alloy
14
Dimensions (L x W x H)
MTBF
Tolerance ±0.02 inch, ±0.5mm
1.26 x 0.78 x 0.42 inches
32.00 x 20.00 x 10.80 mm
1000 K hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Designed to meet IEC/EN/UL60950-1
EN 55032, class A (without external circuit), EN55032 Class B with EMC recommended circuit
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Voltage dips, Short Interruptions & Voltage
variations Immunity
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B (with the recommended EMC circuit)
IEC 61000-4-5, ±2KV, Criteria B (with the recommended EMC circuit)
IEC 61000-4-6, 10 Vrms, Criteria A
Standards
IEC 61000-4-29: 0-70%, Criteria B
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only