欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM10T-1212SNZ 参数 Datasheet PDF下载

AM10T-1212SNZ图片预览
型号: AM10T-1212SNZ
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Converter]
分类和应用:
文件页数/大小: 4 页 / 608 K
品牌: AIMTEC [ AIMTEC ]
 浏览型号AM10T-1212SNZ的Datasheet PDF文件第1页浏览型号AM10T-1212SNZ的Datasheet PDF文件第3页浏览型号AM10T-1212SNZ的Datasheet PDF文件第4页  
Series AM10T-NZ  
10 Watt | DC-DC Converter  
Input Specifications(Continued)  
Parameters  
Nominal  
Typical  
Maximum  
Units  
On  
3.5-12VDC or leave open  
Off  
Input Current when  
Off  
0-1.2VDC or connect to GND, idle current 6-10mA  
Remote On/Off Control  
10  
  
mA  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Resistance  
Conditions  
Typical  
Rated  
1500  
Units  
VDC  
MOhm  
pF  
60 sec  
> 1000  
2000  
Capacitance  
Output Specifications  
Parameters  
Conditions  
Positive Output  
Negative Output  
Typical  
±0.5  
Maximum  
Units  
%
Voltage accuracy  
±1  
Short Circuit protection  
Short Circuit restart  
Over voltage protection  
Line voltage regulation  
LL-HL  
Continuous  
Auto recovery  
>110%  
±0.2  
±0.5  
±0.5  
±5  
Zener diode clamp  
Positive Output  
Negative Output  
5% 100% full load  
0% 5% load  
VDC  
%
%
%
Load voltage regulation  
Temperature coefficient  
Transient recovery time  
Transient recovery deviation  
Full load  
±0.03  
0.3  
%/oC  
mS  
%
25% load step change,  
25% load step change  
20Mhz bandwidth, 5%-  
100% load  
0.5  
±5  
±3  
Ripple & Noise  
40  
mV p-p  
General Specifications  
Parameters  
Switching frequency  
Operating temperature  
Storage temperature  
Cooling  
Conditions  
100% load  
Derating above +71 oC  
Typical  
350  
Maximum  
Units  
KHz  
oC  
-40 to +85  
-55 to +125  
oC  
Free air convection  
Humidity  
Case material  
Weight  
95  
%
g
Aluminum Alloy  
14  
Dimensions (L x W x H)  
MTBF  
Tolerance ±0.02 inch, ±0.5mm  
1.26 x 0.78 x 0.42 inches  
32.00 x 20.00 x 10.80 mm  
1000 K hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)  
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at  
rated output load unless otherwise specified.  
Safety Specifications  
Parameters  
Designed to meet IEC/EN/UL60950-1  
EN 55032, class A (without external circuit), EN55032 Class B with EMC recommended circuit  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient / Burst Immunity  
Surge Immunity  
RF, Conducted Disturbance Immunity  
Voltage dips, Short Interruptions & Voltage  
variations Immunity  
IEC 61000-4-2, Contact ±4KV, Criteria B  
IEC 61000-4-3, 10V/m, Criteria A  
IEC 61000-4-4, ±2KV, Criteria B (with the recommended EMC circuit)  
IEC 61000-4-5, ±2KV, Criteria B (with the recommended EMC circuit)  
IEC 61000-4-6, 10 Vrms, Criteria A  
Standards  
IEC 61000-4-29: 0-70%, Criteria B  
www.aimtec.com  
F 051e R12.C  
Tel: +1 514 620 2722  
2 of 4  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only