Series AM10T-Z
10 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Case/ Input & Output
Resistance
Conditions
60 sec
Typical
Rated
1500
1000
Units
VDC
VDC
MOhm
pF
60 sec
>1000
1000
Capacitance
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
Maximum
Units
%
±1
Cross Regulation (Dual Output)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
25% -100% load on one output, 100% load on second
±5
%
Zener diode clamp
Full Load
150
%
Continuous, hiccup
Auto recovery
Line voltage regulation
HL-LL
±0.5
75
%
%
0% Load to Full Load , Single 5V / 12V / 15V Output
0% Load to Full Load, Other models
±0.5
±1.0
±0.02
Load voltage regulation
Temperature coefficient
Ripple & Noise *
%/oC
mV p-p
20MHz Bandwidth
* Measured with 1µF CC.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Potting material
Conditions
100% load
Full Load with derating above 60ºC
-40 to +125
Typical
330
-40 to +85
Maximum
Units
KHz
oC
oC
100
95
oC
%/ oC
Above 60ºC
2.5
Free air convection
% RH
g
Nickel-coated Copper
UL94V-0 rated
17
Weight
Dimensions (L x W x H)
MTBF
Manual soldering temperature
Transient recovery time
Transient recovery deviation
1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
260
oC
uS
%
25% load step (75%-50%-25%)
25% load step (75%-50%-25%)
200
±3
Safety Specifications
Parameters
Agency approvals
CE, UL
EN55032 Class A, with recommended circuit
IEC61000-4-2, Perf. Criteria A
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A
IEC61000-4-5, Perf. Criteria A (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
Standards
IEC61000-4-8, Perf. Criteria A
IEC/EN/UL 60950-1:2001 & IEC/EN/UL 62368-1
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only