欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM10E-1212SZ 参数 Datasheet PDF下载

AM10E-1212SZ图片预览
型号: AM10E-1212SZ
PDF下载: 下载PDF文件 查看货源
内容描述: 10瓦| DC- DC转换器 [10 Watt | DC-DC Converter]
分类和应用: 转换器电源电路
文件页数/大小: 4 页 / 172 K
品牌: AIMTEC [ AIMTEC ]
 浏览型号AM10E-1212SZ的Datasheet PDF文件第1页浏览型号AM10E-1212SZ的Datasheet PDF文件第3页浏览型号AM10E-1212SZ的Datasheet PDF文件第4页  
Series AM10E-Z  
10 Watt | DC-DC Converter  
Dual output (continued)  
Capacitance  
Efficiency  
load, max  
(%)  
Input Voltage Output Voltage  
Output Current  
max (A)  
Model  
(V)  
(V)  
(μF)  
AM10E-2407DZ  
AM10E-2409DZ  
AM10E-2412DZ  
AM10E-2415DZ  
AM10E-2418DZ  
AM10E-2424DZ  
AM10E-4803DZ  
AM10E-4805DZ  
AM10E-4807DZ  
AM10E-4809DZ  
AM10E-4812DZ  
AM10E-4815DZ  
AM10E-4818DZ  
AM10E-4824DZ  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
±7.2  
±0.69  
±0.555  
±0.416  
±0.333  
±0.27  
±0.208  
±1  
±680  
±470  
±470  
±330  
±220  
±220  
±1000  
±1000  
±680  
±470  
±470  
±330  
±220  
±220  
80  
80  
85  
86  
80  
85  
78  
85  
80  
80  
86  
86  
80  
85  
±9  
±12  
±15  
±18  
±24  
±3.3  
±5  
±7.2  
±9  
±12  
±15  
±18  
±24  
±1  
±0.69  
±0.555  
±0.416  
±0.333  
±0.27  
±0.208  
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at  
rated output load unless otherwise specified.  
Input Specifications  
Parameters  
Nominal  
Typical  
4.5–9  
9-18  
18-36  
36-72  
Maximum  
Units  
5
Voltage range  
VDC  
12  
24  
48  
Filter  
π(PI )  
Turn on Transient process time  
Start up time  
350  
ms  
ms  
20  
5 Vin  
12 Vin  
24 Vin  
48 Vin  
-0.7-15  
-0.7-24  
-0.7-40  
-0.7-80  
Absolute Maximum Rating  
VDC  
Peak Input Voltage time  
No Load Input Current  
Input reflected current  
100  
ms  
mA  
mAp-p  
70  
35  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Resistance  
Conditions  
Typical  
Rated  
1500  
Units  
VDC  
MOhm  
pF  
3 sec  
> 1000  
500  
Capacitance  
Output Specifications  
Parameters  
Voltage accuracy  
Conditions  
Typical  
Maximum  
Units  
%
±1  
Voltage balance (Dual Output)  
Balance Load  
±1  
%
25% load on one output -  
100% load on second load  
Cross Regulation (Dual Output)  
Short Circuit protection  
±5  
%
Continuous  
www.aimtec.com  
F 051e R12.E  
Tel: +1 514 620 2722  
2 of 4  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only