欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM10CW-2412S-NZ-STD 参数 Datasheet PDF下载

AM10CW-2412S-NZ-STD图片预览
型号: AM10CW-2412S-NZ-STD
PDF下载: 下载PDF文件 查看货源
内容描述: [DC/DC Converter; Product Weight (grams): 55; Input voltage min (V): 9; Input voltage max (V): 36; Output voltage min: 12; Output voltage max: 12; Output voltage dual assymetric (y/n): Single; Output Power (W): 10; Max Output current (A): 0.83; Efficiency (%): 87; Max Capacitive load (µF): 470; Package type: 1x1; Mounting: Screw terminal DIN rail; W (in): 2.99; L (in): 1.24; H (in): 1.01; W (mm): 76; L (mm): 31.5; H (mm): 25.7; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 1500; EMC compliance 1: EN 55022 Class A; EMC compliance 2: EN 55022 Class B; Case]
分类和应用:
文件页数/大小: 5 页 / 354 K
品牌: AIMTEC [ AIMTEC ]
 浏览型号AM10CW-2412S-NZ-STD的Datasheet PDF文件第1页浏览型号AM10CW-2412S-NZ-STD的Datasheet PDF文件第2页浏览型号AM10CW-2412S-NZ-STD的Datasheet PDF文件第3页浏览型号AM10CW-2412S-NZ-STD的Datasheet PDF文件第4页  
Series AM10CW-NZ  
10 Watt | DC-DC Converter  
Typical application circuits  
Single  
Dual  
Vin+  
Vin+  
Vin-  
Vo+  
Vo-  
Vo+  
+
+
+
+
10uF  
Com  
Cin  
10uF  
Cin  
+
Vin-  
10uF  
Vo-  
24V input  
48V input  
Cin  
100μF  
10-47μF  
Recommended EMC Circuits  
For EMS test  
For EMI test  
LDM1  
4.7μH  
CY1  
1nF/2KV  
FUSE  
+ Vout  
DC  
+Vout  
-Vout  
+ Vin  
+ Vin  
+
+
DC  
C2  
C3  
C1  
MOV  
10μF  
- Vin  
- Vin  
- Vout  
CY2  
1nF/2KV  
A
B
24V input  
S20K30  
330µF/50V  
1µF/50V  
48V input  
S14K60  
330µF/100V  
1µF/100V  
MOV  
C1/C3  
C2  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 051e R17  
REV: 11/19/A  
Tel: +1 514 620 2722  
5 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only