Series AM1/4S-Z
0.25 Watt | DC-DC Converter
Models
Single output (continued)
Input
Output
Voltage
(V)
24
Output
Current max
(mA)
10.4
Input Current
Full | NoLoad
(mA)
Max
Capacitive
Load (uF)
100
Isolation
(VDC)
Efficiency
(%)
Model
Voltage
(V)
AM1/4S-1224SH30Z
AM1/4S-2403SH30Z
AM1/4S-2405SH30Z
AM1/4S-2407SH30Z
AM1/4S-2409SH30Z
AM1/4S-2412SH30Z
AM1/4S-2415SH30Z
AM1/4S-2418SH30Z
AM1/4S-2424SH30Z
AM1/4S-4803SH30Z
AM1/4S-4805SH30Z
AM1/4S-4807SH30Z
AM1/4S-4809SH30Z
AM1/4S-4812SH30Z
AM1/4S-4815SH30Z
AM1/4S-4818SH30Z
AM1/4S-4824SH30Z
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
43.2-52.8
43.2-52.8
43.2-52.8
43.2-52.8
43.2-52.8
43.2-52.8
43.2-52.8
43.2-52.8
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
38
17
17
18
17
19
19
18
18
9
18
8
7
8
8
10
7
10
10
8
55
60
61
57
62
56
55
57
59
55
53
54
54
55
54
49
49
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
75.7
50
34.7
27.7
20.8
16.6
13.8
10.4
75.7
50
34.7
27.7
20.8
16.6
13.8
10.4
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
10
10
10
9
8
8
8
8
12
15
18
24
10
11
11
8
8
10
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
5
4.5-5.5
12
15
24
48
10.8-13.2
Voltage range
13.5 – 16.5
21.6-26.4
43.2-52.8
VDC
Filter
Capacitor
Turn on transient process time
Start up time
25
ms
ms
200
7
5 Vin
12 Vin
15 Vin
24 Vin
48 Vin
15
17
28
54
100
Absolute maximum rating
VDC
ms
Peak input voltage time
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1000 and 3000
Units
VDC
MOhm
pF
60sec
> 1000
60
Capacitance
Output Specifications
Parameters
Conditions
Typical
±3
Momentary (1sec)
±1.2
±10
±20
Maximum
Units
%
Voltage accuracy
Short circuit protection
Line voltage regulation
Load voltage regulation
Load voltage regulation 3.3V output model
Temperature coefficient
Ripple & noise
For 1% change of Vin
Load 20 – 100%
% of Vin
%
Load 20 – 100%
%
±0.02
100
%/oC
mV p-p
μF
At 20MHz Bandwidth
Capacitive load
100
Rising time
50
ms
www.aimtec.com
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R11.J
Rev: 05/20/A
North America only