Wavelength-Selected, High-Power D2587P-Type (with Wavelength  
Locker)/D2547P-Type Isolated DFB Laser Modules  
Data Sheet, Rev. 2  
July 2001  
Agere Systems’ optoelectronic components are being qual-  
ified to rigorous internal standards that are consistent with  
Telcordia Technologies TR-NWT-000468. All design and  
manufacturing operations are ISO§ 9001 certified. The  
module is being fully qualified for central office applications.  
Description (continued)  
Principles of Operation (Controlled Wave-  
length)  
* Fujikura is a registered trademark of Fujikura Ltd.  
Telcordia Technologies is a trademark of Telcordia Technologies  
Inc.  
§ ISO is a registered trademark of The International Organization for  
Standardization.  
The single-channel, wavelength-selected DFB (ILM) pack-  
age contains internal wavelength-discriminating optics, i.e.,  
two etalons and associated photodiodes. The output con-  
sists of analog signals suitable for controlling the electrical  
current of the thermoelectric cooler (TEC) and the DFB  
laser.  
CORE  
Controlled Feedback  
STRESS ROD  
The module contains an internal optical isolator that sup-  
presses optical feedback in laser-based, fiber-optic sys-  
tems. Light reflected back to the laser is attenuated a  
minimum of 30 dB.  
PRINCIPLE POLARIZATION  
AXIS  
CLADDING  
INNER COATING  
(SILICON & ACRYLATE)  
OUTER COATING  
Controlled Temperature  
1-771(C).a  
An integral TEC provides stable thermal characteristics.  
The TEC allows for heating and cooling of the laser chip to  
maintain a temperature of 25 °C for case temperatures from  
–25 °C to +70 °C. The laser temperature is monitored by  
the internal thermistor, which can be used with external cir-  
cuitry to control the laser chip temperature.  
Figure 1. Polarization-Maintaining Fiber  
Pin Information  
Table 1. Pin Descriptions  
Pin  
D2587P-Type  
Thermistor  
D2547P-Type  
Thermistor  
Controlled Power  
1
2
3
An internal, InGaAs, PIN photodiode functions as the back-  
facet monitor. The photodiode monitors emission from the  
rear facet of the laser and, when used in conjunction with  
control circuitry, can control optical power launched into the  
fiber. Normally, this configuration is used in a feedback  
arrangement to maintain consistent laser output power.  
Thermistor  
Thermistor  
Laser dc Bias  
(Cathode) (–)  
Laser dc Bias  
(Cathode) (–)  
4
5
Back-facet Monitor  
Anode (–)  
Back-facet Monitor  
Anode (–)  
Back-facet Monitor  
Cathode (+)  
TEC (+)1  
Back-facet Monitor  
Cathode (+)  
TEC (+)1  
Standard Package  
6
7
8
9
TEC (–)1  
TEC (–)1  
The laser module is fabricated in a 14-pin, hermetic, metal/  
ceramic butterfly package that incorporates a bias tee that  
separates the dc-bias path from the RF input. The RF input  
has a nominal 25 impedance.  
Case Ground  
λ Photodiode 2 Anode  
Case Ground  
Case Ground  
10 λ Photodiode 1 Anode Case Ground  
The laser module is equipped with Fujikura* polarization-  
maintaining fiber (PMF). The fiber is PANDA type and is the  
same fiber that is used on the Agere Systems Inc. lithium  
niobate modulators. It has a mode field diameter of  
10.5 µm, a cladding diameter of 125 µm ±3 µm, and a  
loose tube jacketed fiber 900 µm in diameter. Figure 1  
shows the orientation of polarization in the fiber.  
11 Laser Anode (+)2  
Laser Anode (+)2  
12 RF Laser Input  
Cathode (–)  
13 Laser Anode (+)2  
RF Laser Input  
Cathode (–)  
Laser Anode (+)2  
14 NC  
Case Ground  
1.A positive current through the thermoelectric heat pump cools the  
laser.  
2.Both leads should be grounded for optimum performance.  