Data Sheet  
November 1999  
L7582 Tip Ring Access Switch  
The SCR may turn on if:  
Switching Behavior (continued)  
The SCR-type protector is used (A code)  
When using an L7582 in the make-before-break mode,  
during the ring-to-idle transition, for a period of up to  
one-half the ringing frequency, the ring break switch  
and the pnpn-type ring access switch can both be in  
the ON state. This is the maximum time after the logic  
signal at INRING has transitioned that the ring access  
switch is waiting for the next zero current cross, so it  
can close. During this interval, current that is limited to  
the dc break switch current-limit value will be sourced  
from the ring node of the SLIC.  
By random probability the ring-to-idle transition  
occurs during a portion of the ring cycle when the  
ringing voltage exceeds the protection circuit SCR  
turn-on voltage.  
Current in excess of the SCR’s turn-on current is also  
available.  
Once the SCR is triggered on, if the SLIC is capable of  
supplying current in excess of the holding current, the  
SCR may be latched on by the SLIC.  
This current is presented to the internal protection cir-  
cuit.  
The probability of this event depends on the character-  
istics of the given SLIC and of the holding current of the  
L7582A device. The SCR hold current distribution is  
designed to be safely away from the test limit of  
80 mA. The higher the distribution, the lower the proba-  
bility of the latch.  
If this situation is of concern for a given board design,  
either use the A series device in the break-before-make  
mode (eliminates the original 25 ms current pulse) or  
use a B series device (eliminates the SCR).  
Table 10. Make-Before-Break Operation  
Ring  
Ring  
Line  
Break  
Switches  
1 & 2  
Return Access Access  
Switch Switch Switches  
ACCESS INPUT TSD  
State  
Timing  
3
4
5 & 6  
0 V  
0 V  
5 V Float Power Ringing  
Open  
Closed Closed  
Open Closed  
Open  
Open  
0 V Float Make-before- SW4 waiting for next zero  
Closed  
break  
current crossing to turn off  
maximum time—one-half of  
ringing. In this transition  
state, current that is limited  
to the dc break switch cur-  
rent-limit value will be  
sourced from the ring node  
of the SLIC.  
0 V  
0 V Float  
Idle/Talk  
Zero cross current has  
occurred.  
Closed  
Open  
Open  
Open  
8
Lucent Technologies Inc.