L7556, L7557 Low-Power SLICs  
with Battery Switch  
Data Sheet  
January 2000  
Recommended Operating Conditions  
Parameter  
Ambient Temperature  
Min  
–40  
4.75  
–24  
–16  
Typ  
Max  
85  
Unit  
°C  
VCC Supply Voltage  
5.0  
–48  
–28  
10  
5.25  
–60  
VBAT1  
ILIM  
45  
V
VBAT1 Supply Voltage  
V
VBAT2 Supply Voltage  
V
Loop Closure Threshold-detection Programming Range  
dc Loop Current-limit Programming Range  
On- and Off-hook 2-wire Signal Level  
ac Termination Impedance Programming Range  
mA  
mA  
Vrms  
5
22  
1
2.2  
150  
600  
1300  
Electrical Characteristics  
Minimum and maximum values are testing requirements. Typical values are characteristic of the device and are  
the result of engineering evaluations. Typical values are for information purposes only and are not part of the test-  
ing requirements. Minimum and maximum values apply across the entire temperature range (–40 °C to +85 °C)  
and the entire battery range unless otherwise specified. Typical is defined as 25 °C, VCC = 5.0 V, VBAT1 = –48 V,  
VBAT2 = –48 V, and ILIM= 40 mA. Positive currents flow into the device. Test circuit is Figure 4 unless noted.  
Table 4. Power Supply  
Parameter  
Min  
Typ  
Max  
Unit  
Power Supply—Powerup, No Loop Current:  
ICC  
2.8  
–2.3  
125  
155  
mA  
mA  
mW  
IBAT (VBAT = –48 V)  
Power Dissipation (VBAT = –48 V)  
Power Supply Rejection 500 Hz to 3 kHz (See Figures 5, 6, 15, and 16.)1:  
35  
45  
dB  
dB  
VCC  
VBAT  
Thermal Protection Shutdown (Tjc)  
175  
60  
°C  
Thermal Resistance, Junction to Ambient (θJA)  
°C/W  
1. This parameter is not tested in production. It is guaranteed by design and device characterization.  
Lucent Technologies Inc.  
7