NetLight 2417K4A 1300 nm Laser
2.5 Gbits/s Transceiver
Data Sheet, Rev. 1
August 2001
Application Information (continued)
Transceiver Processing
When the process plug is placed in the transceiver's optical port, the transceiver and plug can withstand normal
wave soldering and aqueous spray cleaning processes. However, the transceiver is not hermetic, and should not
be subjected to immersion in cleaning solvents. The transceiver case should not be exposed to temperatures in
excess of 125 °C. The transceiver pins can be wave soldered at 250 °C for up to 10 seconds. The process plug
should only be used once. After removing the process plug from the transceiver, it must not be used again as a pro-
cess plug; however, if it has not been contaminated, it can be reused as a dust cover.
Transceiver Optical and Electrical Characteristics
Table 2. Transmitter Optical and Electrical Characteristics (TC = 0 °C to 70 °C; VCC = 3.135 V—3.465 V)
Parameter
Symbol
Min
Max
Unit
Average Optical Output Power (EOL)
Optical Wavelength
PO
λC
–10.0
1266
—
–3.0
1360
4
dBm
nm
nm
dB
Spectral Width
∆λRMS
EXT
Dynamic Extinction Ratio
Output Optical Eye
8.2
—
Compliant with SONET GR-253-CORE and
ITU-T G.957 Eye Mask Requirements
Power Supply Current
ICCT
—
190
mA
Input Data Voltage:
Single Ended*
Differential*
VINp-p
VINp-p
150
300
800
1600
mVp-p
mVp-p
Transmit Disable Voltage†
Transmit Enable Voltage†
VD
VCC – 0.9
VEE
VCC
V
V
VEN
VEE + 0.8
* 50 ¾ load, measured single ended. Differential operation is necessary for optimum performance. (See Figure 2 for visual representation.)
† TTL compatible interface.
Table 3. Receiver Optical and Electrical Characteristics (TC = 0 °C to 70 °C; VCC = 3.135 V—3.465 V)
Parameter
Symbol
Min
Max
Unit
Average Sensitivity:*
800 mV (CML) Differential Input To Transmitter
PI
—
–3
—
–18
—
dBm
dBm
mA
Maximum Input Power*
PMAX
ICCR
Power Supply Current
110
Output Data Voltage:
Single Ended†
Differential†
VOUTp-p
VOUTp-p
300
600
500
1000
mVp-p
mVp-p
Signal-detect Switching Threshold:
Assert
Deassert
LSTD
LSTI
–45
—
–19
–18.5
dBm
dBm
Signal-detect Hysteresis
HYS
0.5
6
dB
Signal-detect Voltage:‡
Low
High
VOL
VOH
0.0
2.4
0.8
VCC
V
V
Signal-detect Response Time
SDRT
—
100
µs
23
–10
* 2 – 1 PRBS with a BER of 1 x 10
.
† 50 ¾ load, measured single ended. Differential operation is necessary for optimum performance.(See Figure 2 for visual representation.)
‡ TTL compatible interface.
4
Agere Systems Inc.