Data Sheet  
September 1999  
1241/1243/1245-Type Uncooled Laser  
Functional Overview (continued)  
V
CC  
LASER  
BACK-FACET  
DETECTOR  
FIBER PIGTAIL  
15 k•  
(2)  
(+)  
LASER BIAS MONITOR VOLTAGE  
(4)  
(–)  
15 k•  
15 k•  
(19)  
(+)  
LASER BACK-FACET MONITOR VOLTAGE  
15 k•  
(17)  
(–)  
IBF  
BAND GAP  
AUTOMATIC POWER  
10 •  
REFERENCE  
CONTROL CIRCUITRY  
TEMPERATURE  
SENSOR  
(16)  
t
DATA  
INPUT DATA  
COMPARATOR  
30 k•  
30 k•  
I
BIAS  
MODULATION  
CIRCUITRY  
V
CC – 1.3 V  
I
MOD  
(15)  
DATA  
(7)  
TRANSMITTER  
DISABLE  
1-868(C).h  
Figure 1. Simplified Transmitter Schematic Input Data  
Input Data  
input signal, the optical signal will be the complement  
of the data input signal.  
Data enters the transmitter through a comparator.  
These inputs have internal pull-down resistors to a volt-  
age reference that is 1.3 V below VCC. This configura-  
tion allows the transmitter to be driven from either a  
single-ended or a differential input signal. Since the  
input is a comparator instead of a gate, the absolute  
input signal levels are not important when the inputs  
are driven differentially. When driven single-ended,  
however, the input signal voltage should be centered  
around VCC – 1.3 V to eliminate pulse-width distortion.  
With a single-ended input, either input can be used and  
the unused input can be left as an open circuit due to  
the internal reference shown in Figure 1. The optical  
output signal will be in the same sense as the input  
data—an input logic high turns the laser diode on and  
an input logic low turns the laser diode off. However, if  
the negative input is used with a single-ended data  
The differental inputs of the 1241 Gbit versions are ter-  
minated internally with 100 between the DATA and  
DATA inputs.  
Minimum Data Rate  
Because the modulation and bias control circuitry are  
influenced by the input data pattern, the standard  
transmitter cannot be used in burst-mode type applica-  
tions. For burst-mode applications, please contact your  
Agere Account Manager. The minimum data rate  
(pseudorandom data, 50% average duty cycle) for the  
1241/1243/1245-Type Transmitters is approximately  
1 Mbit/s.  
Agere Systems Inc.  
3