AMC2576
Note 1: External components such as the catch diode, inductor, input and output capacitors can affect switching regulator system performance.
Refer to Application Information for details.
Note 2: The oscillator frequency reduces to approximately 11kHz in the event of fault conditions, such as output short or overload. And the
regulated output voltage will drop approximately 40% from the nominal output voltage. This self-protection feature lowers the average
power dissipation by lowering the minimum duty cycle from 5% down to approximately 2%.
Note 3: For these parameters, FB is removed from VOUT and connected to +12V to force the output transistor OFF.
Note 4: VOUT pin sourcing current. No diode, inductor or capacitor connect to VOUT.
Note 5: FB is removed from VOUT and connected to 0V.
Copyright © 2006 ADDtek Corp.
5