GENERAL DESCRIPTION  
both voltage and current outputs.  
The 3B18 is a wideband (20kHz) single-channel signal  
conditioning module which interfaces, amplifies, and filters  
signals from balanced 4-arm full-bridge strain-gage bridges  
with a resistance from 100to 10 k, providing simultaneous  
precision voltage and current outputs. The module provides two  
user-selectable (via front-panel switches) bridge excitation  
voltages: +10 V for bridges with a load impedance down to  
300W or +3.33V for 120W bridges or others below 300W.  
Module bandwidth is also user-selectable between 20 kHz and  
100 Hz, with user-supplied filter capacitors installed in the  
optional AC1310 ranging card. The 3B18 protects the computer  
side from damage due to field-side over-voltage faults up to  
130V rms. In addition, the current output withstands 130V rms  
without damage and interfaces user equipment through screw  
terminals located on the 3B Series backplane. The 3B18 is a  
plug-in, mix-and-match, hot-swappable module which is easily  
field calibrated via front-panel zero and span adjustments for  
3B Series Custom-Ranging Program – Externally-  
programmable Model 3B18-00, enables the user to configure a  
special input range by using the optional plug-on AC1310  
ranging card, which houses user-supplied resistors to determine  
zero and span. To facilitate selecting resistors, a Windows  
program, 3B-CUSTOM, calculates resistor values based on the  
user-desired input/output ranges.  
A chopper-stabilized low-drift (+1uV/oC) input amplifier  
assures long-term stability. For user convenience, the zero and  
span can be factory configured to meet custom range needs  
(Model 3B18-CUSTOM) or can be externally programmed  
(Model 3B18-00) via user supplied resistors inserted in the  
optional AC1310 plug-on ranging card.  
.
.
Figure 2  
Rev. 0 | Page 2 of 8