欢迎访问ic37.com |
会员登录 免费注册
发布采购

A1020B-3PL84I 参数 Datasheet PDF下载

A1020B-3PL84I图片预览
型号: A1020B-3PL84I
PDF下载: 下载PDF文件 查看货源
内容描述: ACT 1系列FPGA [ACT 1 Series FPGAs]
分类和应用: 现场可编程门阵列可编程逻辑时钟
文件页数/大小: 24 页 / 163 K
品牌: ACTEL [ Actel Corporation ]
 浏览型号A1020B-3PL84I的Datasheet PDF文件第1页浏览型号A1020B-3PL84I的Datasheet PDF文件第2页浏览型号A1020B-3PL84I的Datasheet PDF文件第3页浏览型号A1020B-3PL84I的Datasheet PDF文件第4页浏览型号A1020B-3PL84I的Datasheet PDF文件第6页浏览型号A1020B-3PL84I的Datasheet PDF文件第7页浏览型号A1020B-3PL84I的Datasheet PDF文件第8页浏览型号A1020B-3PL84I的Datasheet PDF文件第9页  
A C T  
1 S e r i e s F P G A s  
P R A  
P r o b e A (O u t p u t )  
P i n D e s c r i p t i o n  
The Probe A pin is used to output data from any user-defined  
design node within the device. This independent diagnostic  
pin is used in conjunction with the Probe B pin to allow  
real-time diagnostic output of any signal path within the  
device. The Probe A pin can be used as a user-defined I/O  
when debugging has been completed. The pins probe  
capabilities can be permanently disabled to protect the  
programmed designs confidentiality. PRA is active when the  
MODE pin is HIGH. This pin functions as an I/O when the  
MODE pin is LOW.  
C LK  
C lo c k (In p u t )  
TTL Clock input for global clock distribution network. The  
Clock input is buffered prior to clocking the logic modules.  
This pin can also be used as an I/O.  
DC LK  
Dia g n o s t ic C lo c k (In p u t )  
TTL Clock input for diagnostic probe and device  
programming. DCLK is active when the MODE pin is HIGH.  
This pin functions as an I/O when the MODE pin is LOW.  
G N D  
G r o u n d  
P R B  
P r o b e B (O u t p u t )  
Input LOW supply voltage.  
The Probe B pin is used to output data from any user-defined  
design node within the device. This independent diagnostic  
pin is used in conjunction with the Probe A pin to allow  
real-time diagnostic output of any signal path within the  
device. The Probe B pin can be used as a user-defined I/O  
when debugging has been completed. The pins probe  
capabilities can be permanently disabled to protect the  
programmed designs confidentiality. PRB is active when the  
MODE pin is HIGH. This pin functions as an I/O when the  
MODE pin is LOW.  
I/O  
In p u t /O u t p u t (In p u t , O u t p u t )  
I/O pin functions as an input, output, three-state, or  
bidirectional buffer. Input and output levels are compatible  
with standard TTL and CMOS specifications. Unused I/O pins  
are automatically driven LOW by the ALS software.  
MO DE  
Mo d e (In p u t )  
The MODE pin controls the use of multifunction pins (DCLK,  
PRA, PRB, SDI). When the MODE pin is HIGH, the special  
functions are active. When the MODE pin is LOW, the pins  
function as I/O. To provide Actionprobe capability, the MODE  
pin should be terminated to GND through a 10K resistor so  
that the MODE pin can be pulled high when required.  
S DI  
S e r ia l Da t a In p u t (In p u t )  
Serial data input for diagnostic probe and device  
programming. SDI is active when the MODE pin is HIGH. This  
pin functions as an I/O when the MODE pin is LOW.  
N C  
N o C o n n e c t io n  
This pin is not connected to circuitry within the device.  
V
S u p p ly Vo lt a g e  
C C  
Input HIGH supply voltage.  
1
R e c o m m e n d e d O p e r a t i n g C o n d i t i o n s  
A b s o l u t e M a x i m u m R a t i n g s  
Free air temperature range  
Parameter  
Commercial Industrial  
Military  
Units  
Symbol Parameter  
Limits  
Units  
Temperature  
Range  
0 to  
+70  
–40 to  
+85  
–55 to  
+125  
1
°C  
2
V
V
DC Supply Voltage  
Input Voltage  
–0.5 to +7.0  
Volts  
CC  
I
PowerSupply  
Tolerance  
–0.5 to V +0.5 Volts  
CC  
±5  
±10  
±10  
%V  
CC  
V
I
Output Voltage  
I/O Sink/Source  
–0.5 to V +0.5 Volts  
CC  
O
Note:  
±20  
mA  
1. Ambient temperature (T ) used for commercial and industrial;  
IO  
A
3
case temperature (T ) used for military.  
Current  
C
T
Storage Temperature  
–65 to +150  
°C  
STG  
Notes:  
1. Stresses beyond those listed under “Absolute Maximum Ratings”  
may cause permanent damage to the device. Exposure to  
absolute maximum rated conditions for extended periods may  
affect device reliability. Device should not be operated outside  
the Recommended Operating Conditions.  
2. V = V , except during device programming.  
PP  
CC  
3. Device inputs are normally high impedance and draw  
extremely low current. However, when input voltage is greater  
than V + 0.5 V or less than GND – 0.5 V, the internal protection  
CC  
diode will be forward biased and can draw excessive current.  
1 -2 8 7