5. Performance
5-1. Maximum Ratings
Rating
Value
10
Unit
dBm
V
Input Power Level
DC Voltage
P
VDC
Tstg
TA
5
Storage Temperature Range
Operable Temperature Range
-40 to +85
-20 to +75
℃
℃
5-2. Electronic Characteristics
Characteristic
Min.
Typ.
Max.
Unit
Center Frequency
3dB Bandwidth
Insertion Loss
fC
BW3
IL
925.00
18.5
MHz
MHz
922.00 …. 928.00 MHz
922.00 …. 928.00 MHz
--
2.9
0.4
4.2
2.0
dB
dB
Amplitude Ripple
” ±
±
Absolute Attenuation
775.00 …. 835.00 MHz
40
36
36
38
54
47
55
52
--
--
--
--
dB
dB
dB
dB
835.00 …. 895.00 MHz
970.00 …. 992.00 MHz
992.00 …. 1075.0 MHz
Input / Output Impedance
50 ©
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
C ACT 2003. All Rights Reserved.
○
NOTE:
1. The frequency fC is defined as the midpoint between the 3dB frequencies.
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50© test system with VSWRd1.2:1.
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
4. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence
without notice.
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies..