5. Performance  
5-1.Maximum Ratings  
Item  
Symbol  
Rating  
Units  
Input Power  
DC Voltage  
Pin  
15  
3
dBm  
V
VDC  
Operating Temperature Range  
Storage Temperature Range  
TA  
-10 ~ +60  
-40 ~ +85  
°C  
Tstg  
°C  
5-2.Electronic Characteristics  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Centre frequency  
Port 1  
fC  
--  
--  
914.500  
959.500  
--  
--  
MHz  
MHz  
Port 2  
Insertion loss  
IL  
--  
--  
3.5  
3.5  
4.5  
4.5  
dB  
dB  
Port 1: 914.000…915.000 MHz  
Port 2: 959.000…960.000 MHz  
Amplitude ripple(p-p)  
Δα  
--  
--  
0.7  
0.7  
2.0  
2.0  
dB  
dB  
Port 1: 914.000…915.000 MHz  
Port 2: 959.000…960.000 MHz  
Absolute attenuation Port 1  
α
30  
35  
--  
dB  
959.000…960.000 MHz  
Absolute attenuation Port 2  
α
30  
35  
--  
--  
dB  
914.000…915.000 MHz  
Temperature coefficient of frequency  
TCf  
--  
-30  
ppm/K  
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!  
1. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is  
connected to a 50Ω test system with VSWR1.2:1. The test fixture L and C are adjusted for minimum insertion  
loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on  
the impedance matching component values and quality.  
2. Unless noted otherwise, specifications apply over the entire specified operating temperature range.  
3. The specifications of this device are based on the test circuit shown above and subject to change or  
obsolescence without notice.  
4. All equipment designs utilizing this product must be approved by the appropriate government agency prior to  
manufacture or sale.  
5. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,  
processes and circuits implemented within components or assemblies.  
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.  
ISO9001: 2000 Registered - Registration number 6830/2  
Issue : 1 C1  
Date : SEPT 04  
For quotations or further information please contact us at:  
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK  
http://www.actcrystals.com