5-2.Electronic Characteristics  
Characteristic  
Minimum  
Typical  
Maximum  
Unit  
Centre Frequency  
fC  
(Centre frequency between 3dB points)  
--  
--  
419.200  
3.0  
--  
MHz  
dB  
Insertion Loss  
IL  
4.5  
3dB Pass band  
BW3  
±600  
38  
kHz  
at fC -21.4MHz (Image)  
30  
24  
--  
--  
--  
Rejection  
dB  
at fC -10.7MHz (LO)  
Ultimate  
32  
60  
--  
Turnover Temperature  
Turnover Frequency  
Frequency Temperature Coefficient  
TO  
fO  
25  
55  
°C  
Temperature  
fC  
0.032  
10  
MHz  
ppm/°C2  
FTC  
|fA|  
Frequency Aging - Absolute Value during the First Year  
ppm/yr  
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!  
1. The frequency fC is defined as the midpoint between the 3dB frequencies.  
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is  
connected to a 50 Ω test system with VSWR 1.2:1. The test fixture L and C are adjusted for minimum insertion  
loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on  
the impedance matching component values and quality.  
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.  
4. Frequency aging is the change in fC with time and is specified at +65°C or less. Aging may exceed the  
specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after  
manufacture, decreasing in subsequent years.  
5. Turnover temperature, T0, is the temperature of maximum (or turnover) frequency, f0. The nominal frequency at  
any case temperature, TC, may be calculated from: f = f0 [1 - FTC (T0 - TC)2].  
6. The specifications of this device are based on the test circuit shown above and subject to change or  
obsolescence without notice.  
7. All equipment designs utilizing this product must be approved by the appropriate government agency prior to  
manufacture or sale.  
8. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,  
processes and circuits implemented within components or assemblies.  
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.  
ISO9001: 2000 Registered - Registration number 6830/2  
For quotations or further information please contact us at:  
Issue : 1 C1  
Date : SEPT 04  
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK  
http://www.actcrystals.com  